FEATURE
OR CAPABILITY |
SubSurface
LC-2100
|
SubSurface
LC-2500
|
Main
Unit Processing Time |
2.5
to 4.0 sec |
1.0
sec max. |
Transmitter
Radio Output Power |
100
milliWatts |
500
milliWatts |
Main
Unit LCD Display Size |
73
mm by 50 mm |
96
mm by 75 mm |
Main
Unit Operating Temperature |
0
to 40 C |
-10
to 50 C |
Maximum
No. of Summations |
99 |
999 |
LCD
Display Temperature Control |
None |
Automatic
Compensation |
Main
Unit Weight (includes batteries) |
5.5
lb |
6.9
lb |
Time
Difference (Td) Resolution |
100
microsec minimum |
25
microsec minimum |
Time
Difference (Td)Maximum |
800
milllisec |
1600
millisec |
Peak
Sensitivity of Sensors |
600
Hz, ± 100 Hz |
500
Hz, ± 100 Hz |
Signal/Noise
Ratio, Std Sensors |
Excellent |
Twice Ratio
of
LC-2100
|
Low
Frequency Sensors or
Hydrophones for PVC |
Red
Sensors Only |
Both
Red Sensors
& Hydrophones (new) |
Dynamic
Range with Std Sensors |
90
dB |
100
dB |
|